PIV Unit Installation glossary

The terms you'll come across, explained in plain English.

Approved Document F
The part of the Building Regulations guidance in England covering ventilation, including minimum extract rates for kitchens and bathrooms and background ventilation requirements.
Black mould
A common name for dark mould growth caused by persistent damp surfaces, often from condensation. It needs cleaning off and the underlying moisture problem fixing.
Condensation
Water that forms when warm, moist air touches a surface colder than its dew point, such as windows, external corners and the backs of wardrobes on outside walls.
Core drilling
Cutting a clean, round hole through a wall with a diamond core drill. Wall-mounted PIV units need one through an external wall to draw in outside air.
Dew point
The temperature at which air can no longer hold its moisture and water starts to form on surfaces. Lower humidity means a lower dew point and less condensation.
Diffuser
The round grille fitted in the ceiling or wall where air from a PIV unit enters the living space. It spreads the airflow so it does not feel like a draught.
Extract fan
A fan in a kitchen or bathroom that removes moist air at source and ducts it outside. Building Regulations set minimum extract rates when fans are installed or replaced.
Fused spur
A fixed electrical connection with its own fuse that supplies a single appliance, such as a PIV unit in the loft. New spurs must be installed to BS 7671.
HHSRS
The Housing Health and Safety Rating System, used in England to assess hazards in homes, including damp and mould growth. Councils can require landlords to remove serious hazards.
MVHR
Mechanical ventilation with heat recovery. A ducted whole-house system that extracts stale air and supplies fresh air through a heat exchanger, best suited to new or very airtight homes.
Positive input ventilation (PIV)
A ventilation system that gently supplies filtered air into a home from the loft or outside, creating slight positive pressure that pushes moist, stale air out through natural gaps.
Positive pressure
A slightly higher air pressure inside the house than outside. It makes air flow outwards through small gaps, carrying moisture with it instead of letting it settle.
Relative humidity
How much moisture the air holds compared with the maximum it could hold at that temperature, shown as a percentage. High readings over long periods encourage mould.
Summer setting
A feature that reduces airflow or stops the unit pushing in loft air when it is hotter than a set temperature, avoiding warm air entering the house on hot days.
Tempering heater
A small heater built into many PIV units that warms incoming air when it falls below a set temperature, so the supply stays comfortable in cold weather.
Trickle vent
A small slotted vent, usually in a window frame, that allows a steady low level of background ventilation even when the window is closed.